Beaver Coach Contessa 2007

Model Contessa made in 2007 by Beaver Coach got 3 recalls as well as 3 service bulletins. Technical service bulletines regarding engine and engine cooling and fuel system, gasoline. There were some recalls concerningengine and engine cooling and equipment.

Model 2007

Recalls


CampaignManufacturerManufacturing dateType# of units affectedDate Owner notified MfgRecall Initiated byManufacturers of recalled vehicles/productsReport Recieved DateRecord Creation DateRegulation Part NumberFMVSS Number
ENGINE AND ENGINE COOLING - ENGINE - DIESEL
07V311000MONACO COACH CORPORATIONfrom 11/21/2005 to 08/09/2006V (Vehicle)74708/07/2007MFRMONACO COACH CORPORATION07/20/200707/20/2007
Defect SummaryOn certain motor homes built with cummins isl cm850 diesel engines, the connecting rod contains a machining defect in the wrist pin bushing of the rod that could cause a seizure of the piston pin.
Consequence SummaryIf allowed to progress, this can lead to engine failure with the possibility of the rod rupturing the lock cavity, oil and debris on the roadway and vehicle crash.
Corrective SummaryMonaco is working with cummins to recalibrate the engine control module and enhance the engine protection system enabling it to provide early detection of the failure mode and avoid more serious engine damage and resultant safety hazard. cummins will also install a new valve cover with a crankcase pressure sensor free of charge (please see 07e033). owners may contact cummins at 800-343-7357 or monaco at 1-800-685-6545.
NotesMonaco recall no. r07007.customers may contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty: 1-800-424-9153); or go to http://www.safercar.gov.
EQUIPMENT - RECREATIONAL VEHICLE
07V404000MONACO COACH CORPORATIONfrom 12/12/2006 to 05/23/2007V (Vehicle)63012/14/2007MFRMONACO COACH CORPORATION09/06/200709/06/2007
Defect SummaryOn certain motor homes equipped with atwood sealed burner ranges, the range and slide-in burner tubes leading from the gas manifold to the burner heads had a depression or 'kink' in the exterior bend restricting proper airflow and gas mixture.
Consequence SummaryThis condition could result in carbon monoxide poisoning.
Corrective SummaryMonaco is working with atwood to have the tubes replaced on these ranges. the recall began on december 14, 2007. owners may contact atwood at 1-800-348-7418 or monaco at 1-800-685-6545.
NotesCustomers may also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to http://www.safercar.gov.
EQUIPMENT - RECREATIONAL VEHICLE - LPG TANK ASSEMBLY
06V429000MONACO COACH CORPORATIONfrom 03/14/2006 to 10/12/2006V (Vehicle)20612/05/2006MFRMONACO COACH CORPORATION11/14/200611/14/2006
Defect SummaryOn certain class a motor homes, heat shields were not installed in the lp tank bay.
Consequence SummaryThe heat from the hydrohot exhaust could place excessive temperature on the exterior of the lp tank and result in unexpected venting of lp gas through the lp tank safety relief valve. lp gas leakage in the presence of an ignition source could result in a fire.
Corrective SummaryDealers will install a heat shield between the hydrohot exhaust and the lp tank at no cost to you. the recall began on december 5, 2006. owners may contact monaco at 1-800-685-6545.
NotesMonaco recall no. r06036.customers may also contact the national highway traffic safety administration

Bulletins


BulletinBulletin dateReplacement BulletinItem no.SummaryAdded
ENGINE AND ENGINE COOLING - ENGINE
08-04-0205/05/200810025621Monaco coach corporation has been advised that cummins inc. has initiated a service campaign bulletin c0805 pertaining to certain isc and isl engines. *pe08/26/2008
FUEL SYSTEM, GASOLINE - FUEL INJECTION SYSTEM - FUEL RAIL
08-04-0205/05/200810025621Monaco coach corporation has been advised that cummins inc. has initiated a service campaign bulletin c0805 pertaining to certain isc and isl engines. *pe08/26/2008
STRUCTURE - BODY - ROOF AND PILLARS
17505/21/200810025345Re-seal of the roof will be necessary to reduce the possibility of water leaks. csc was received. *pe07/30/2008