FUEL SYSTEM, GASOLINE
06E043000HONEYWELL INTERNATIONAL, INC. E (Equipment)8830310/18/2006MFRGENERAL MOTORS CORP.05/19/200605/22/2006
Defect SummaryCertain replacement fuel filters, fram brand name p/n g3727, with date codes x52911 through x60801 sequentially or x600141 and a mexico country or origin marking on the fuel filter housing manufactured from october 18, 2005, through march 21, 2006, sold for use on the vehicles listed above and on certain school buses. (to see the school bus engine sizes, click on document search and then bus applications). the connector on the fuel filter was not manufactured to honeywell's specification. as a result, the o-ring may not seat correctly on the fuel line.
Consequence SummaryThis condition may cause an inadequate seal at the connection, potentially leading to a fuel leak. in the presence of an ignition source, a fire could occur.
Corrective SummaryHoneywell will notify owners and replace the fuel filters free of charge. the recall began on october 18, 2006. owners may contact fram customer service at 1-800-890-2075 (option 1).
NotesThis recall only pertains to aftermarket fram fuel filters and has no relation to any original equipment installed on the vehicles listed.customers may contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty: 1-800-424-9153); or go to http://www.safercar.gov.
FUEL SYSTEM, GASOLINE - DELIVERY - HOSES, LINES/PIPING, AND FITTINGS
06E041000R&B, INC. E (Equipment)780005/04/2006MFRGENERAL MOTORS CORP.05/18/200605/18/2006
Defect SummaryCertain r&b, inc. central multiport fuel injection (cmfi) fuel return lines, models help 55163, napa balkamp 700-3270, and the connection 2560001, sold for use as replacement equipment for the vehicles listed above. the fuel return line has a mechanical bleed valve which was not installed at the proper torque.
Consequence SummaryA fuel leak can occur at the valve, possibly resulting in a fire.
Corrective SummaryR&b, inc. will notify owners and at the customers request, either replace the fuel line or offer a full refund. the recall began on may 4, 2006. owners may contact r&b, inc. at 215-712-5330.
NotesThis recall only pertains to r&b, inc. aftermarket cmfi return fuel lines and has no relation to any original equipment installed on the listed passenger vehicles.customers may contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty: 1-800-424-9153); or go to http://www.safercar.gov.

Bulletins


BulletinBulletin dateReplacement BulletinItem no.SummaryAdded
FUEL SYSTEM, GASOLINE - DELIVERY - FUEL PUMP
66630904/01/199752350Engine hard to start (replace fuel pump pulsator). *tw07/24/1997
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY - FILLER PIPE AND CAP
56630408/01/199545806Fuel tank noise, fuel gage inaccurate, reduced fuel capacity.*sd04/25/1996

Consumer Complaints


Fail datemilesoccurencesPurchase date
FUEL SYSTEM, GASOLINE - CARBURETOR SYSTEM
03/01/199803/01/1998
 Failed intake gaskets, caused anti-freeze to contaminate oil. engine bearing failure and was replaced. *ak
FUEL SYSTEM, GASOLINE - DELIVERY
09/02/20011009/01/2001
 The feed and fuel lines are manufactured of polycarbinate - plastic- that will harden, crack; thereby exposing risks to the public at large. additionally, the fuel pressure regulator diaphram is under high pressure compared to other chevrolet models. for example, a pontiac 6000 operates at approx 40 lbs psi fuel pressure. the chevrolet s-10 blazer cmpi fuel system operates at approx. 60 lps. psi. *ak
FUEL SYSTEM, GASOLINE - DELIVERY - FUEL PUMP
09/09/200437670108/06/1993
 Dt*: the contact stated while driving 5 mph and attempting to depress the accelerator pedal, the vehicle would not accelerate. there seemed to be no gas moving though the fuel line. at times, there was difficulty in starting the vehicle. it was taken to a service dealer who inspected the fuel tank for accessibility. the fuel tank was replaced and a new fuel pump was installed. there was a nhtsa recall # 06e041000 regarding the fuel system, gasoline:delivery:hoses, lines/piping, and fittings on the year, make and model of this vehicle however the manufacturer was not contacted to verify if the vehicle was included in the recall.
10/15/20042000002
 I have a 93 s10 blazer and the truck shut down while my daughter was driving. the ecmb fuse was blown and would blow out when the ignition switch would be turned on. i finally tracked the problem down to the fuel pump. when i removed the gas tank and pulled out the fuel pump, the wire inside the tank were welded together and the plug on the end of the fuel pump was melted (fused) together. this really concerns me that these internal components can get hot enough to melt they could easily cause the tank to explode. also the wiring is attached to the sending unit and to replace both of these components it will cost over $600 just for parts. this is a terrible design and a nasty hazard, somebody may be killed. *jb
10/21/19971
 Fuel pump failed.
08/01/19974
 While driving at any speed for no reason the blazer stalls, will not restart and has to be towed. this has happened on (4) different occasions. the fuel pump has been changed (5) times because there is no pressure in the pump. the vehicle has stopped working again and has to be towed a (5th) time. *ak
08/27/1993
 Fuel pump failed, resulting in shutdown, replaced 3 times. tt
 Fuel injectors, oxygen & map sensors, and fuel pump has caused vehicle to become inoperative. please describe details. tt
FUEL SYSTEM, GASOLINE - DELIVERY - HOSES, LINES/PIPING, AND FITTINGS
09/09/200437670108/06/1993
 Dt*: the contact stated while driving 5 mph and attempting to depress the accelerator pedal, the vehicle would not accelerate. there seemed to be no gas moving though the fuel line. at times, there was difficulty in starting the vehicle. it was taken to a service dealer who inspected the fuel tank for accessibility. the fuel tank was replaced and a new fuel pump was installed. there was a nhtsa recall # 06e041000 regarding the fuel system, gasoline:delivery:hoses, lines/piping, and fittings on the year, make and model of this vehicle however the manufacturer was not contacted to verify if the vehicle was included in the recall.
03/31/1997
 Driving the vehicle at speed of 50mph, the fuel line pulled a part the crimp, causing a fuel leak under the under carriage. *ak
FUEL SYSTEM, GASOLINE - FUEL INJECTION SYSTEM
11/22/2002
 Consumer stated that while driving and without the injection pump failed after dealer of repair the vehicle. dealer notified. mr
02/12/2001111/01/2095
 Faulty main/central injector was dumping gas all over - very dangerous - i am told by several mechanics that they are replacing this part like crazy - that they believe this part to be defective - dealer replaced for another customer but would not honor same for me.*ak
09/02/20011009/01/2001
 The feed and fuel lines are manufactured of polycarbinate - plastic- that will harden, crack; thereby exposing risks to the public at large. additionally, the fuel pressure regulator diaphram is under high pressure compared to other chevrolet models. for example, a pontiac 6000 operates at approx 40 lbs psi fuel pressure. the chevrolet s-10 blazer cmpi fuel system operates at approx. 60 lps. psi. *ak
01/01/2002
 There was problems with fuel injection because fuel injection kept on cutting off, and would stall out when the consumer was driving. contacted an independent mechanic to do the work on vehicle.*ak
07/17/20002
 Vehicle experienced failure of the manufacturers recall component (99034) on two occasions prior to recall notification, consumer requesting reimbursement. *mjs
07/23/19991004/01/1993
 I over took care of this truck as i loved it so much. it now repulses me to look at it. i thought that maybe it was a lemon but my brother had one a year older that had the same engine problems with the radiator,alternator repairs fuel injection, roller cam, engine replacement @ 73,000 miles only he dumped his before the engine need replaced and no customer service from gm. the only way its like a rock is when it sinks in a lake! i called gm got a case #990448783 (8/9/99) but now it has a new engine it still sound like the alternator is going every time i have it looked at it cost $200.00 and they find some thing else. when i have the money to dump it i will and i will never own another gm product i'm now $5,600 into this but it will be my last gm truck or product.
12/23/1999207/01/1999
 No summary listed for above vehicle. *ak
12/01/1999104/01/1993
 I only what to report that there are many coi units failling on these chevrolets 4.3 moyors and what happes is a part of the fuel injection called the 'cpi' unit breaks and pumps gasoline into a com partment of the motor and could cause a fire!!!!!!! mines bee repaired,but after asking arround( outher repair shops ) ive found these units are being replaced on a regulair bassis any where after 60000 miles!!! has any one else written too you about this?? fred. *ak
03/16/1999111/01/1998
 No summary
01/01/1994305/20/1993
 The rear seat belt buckle are hard to latch and unlatch; also, when appling the brakes there is a noise, pedal goes almost to the floor, have abs anti-lock brakes. consumer states the front passenger seat belt never worked properly. brake pads were replaced with 25336 miles. engine missing upon acceleration. poor gas mileage. *slc
FUEL SYSTEM, GASOLINE - FUEL INJECTION SYSTEM - INJECTORS
 Fuel injectors, oxygen & map sensors, and fuel pump has caused vehicle to become inoperative. please describe details. tt
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY
03/20/1997
 When the gas tank was filled, there was a smell of gas fumes in the vehicle and the fuel tank would leak from the top of the tank because of corrosion. the fuel tank has been replaced. *ak
01/17/19971
 While driving, smelled oil, noticed big puddle of oil under motor area, oil leaking from adapter plate assembly. could cause fire, whole undercarraige coated with oil. *ak
FUEL SYSTEM, OTHER - DELIVERY - FUEL PUMP
07/09/20071200002
 Tl*the contact owns a 1993 chevrolet blazer. the contact stated that there was an electric fuel pump inside the vehicle. while driving 20 mph, the wiring became hot and melted the wiring plug. as a result, the fuel pump shut off and the vehicle would not operate. the contact had not taken the vehicle to be inspected. the fuel pump and fuel fending unit were replaced, but the failure recurred. the purchase date was unknown. the current mileage was 125,000 and failure mileage was 120,000.