Recalls
Campaign | Manufacturer | Manufacturing date | Type | # of units affected | Date Owner notified Mfg | Recall Initiated by | Manufacturers of recalled vehicles/products | Report Recieved Date | Record Creation Date | Regulation Part Number | FMVSS Number | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FUEL SYSTEM, GASOLINE | ||||||||||||||||
06E056000 | UFI FILTERS USA | E (Equipment) | 58640 | 08/04/2006 | MFR | FORD MOTOR COMPANY | 06/13/2006 | 06/23/2006 | ||||||||
Defect Summary | Certain aftermarket fuel filters sold under the purolator brand name, p/n f65277, shipped from january 16 through june 2, 2006, for use on the above listed passenger vehicles. due to incorrect design, the quick connectors may not fully seat with the tube interface, even though the person making the connection may believe that the quick connector is fully attached. | |||||||||||||||
Consequence Summary | Failure of this connection could lead to fuel spillage and, in the presence of an ignition source, a fire could occur. | |||||||||||||||
Corrective Summary | Ufi will notify owners and replace the filters free of charge. the recall began on august 4, 2006. owners may contact ufi filters usa at 800-230-5876. | |||||||||||||||
Notes | This recall only pertains to ufi filters usa (purolator) aftermarket fuel filters and has no relation to any original equipment installed on the listed passenger vehicles.customers may contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty: 1-800-424-9153); or go to http://www.safercar.gov. | |||||||||||||||
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY | ||||||||||||||||
02I003000 | FORD MOTOR COMPANY | from 07/01/1992 to 10/21/2002 | I | 350000 | ODI | FORD MOTOR COMPANY | 10/15/2002 | 11/21/2002 | ||||||||
Defect Summary | In order to enhance police office safety, model year 1992-2003 crown victoria police interceptor (cvpi) vehicles will be equipped with shields designed to help protect the fuel tank in high-speed rear-impact crashes. ford also will be offering an optional trunk package designed to improve the safe transport of sharp-edged, heavy equipment in these vehicles. | |||||||||||||||
Consequence Summary | Some high-speed rear-impact crashes have resulted in fuel tank punctures and fires in cvpi vehicles. | |||||||||||||||
Corrective Summary | Ford has advised us that shield kits have been available since late october and will be installed on police interceptor vehicles at no cost. the optional trank package will be available by the end of 2002. ford has established a new web site at www.cvpi.com to answer additional questions about the safe use of cpvi vehicles. | |||||||||||||||
Notes | Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236). | |||||||||||||||
FUEL SYSTEM, OTHER - STORAGE - TANK ASSEMBLY | ||||||||||||||||
03V472000 | FORD MOTOR COMPANY | V (Vehicle) | 4218 | 01/07/2004 | ODI | FORD MOTOR COMPANY | 11/06/2003 | 11/19/2003 | ||||||||
Defect Summary | On certain natural gas vehicles, if a flame from a vehicle interior fire becomes locally directed at the natural gas fuel tank located immediately behind the rear seat, the flame could damage the fiberglass wrap on the tank weakening the tank. | |||||||||||||||
Consequence Summary | If the strength of the tank is significantly compromised, it could rupture, increasing the risk of a fire. | |||||||||||||||
Corrective Summary | Dealers will install an insulator behind the current seat back. owner notification began on january 7, 2004. owners should contact ford at 1-800-392-3673. | |||||||||||||||
Notes | Ford recall no. 03s08.customers can also contact the national highway traffic safety administration |
Bulletins
Bulletin | Bulletin date | Replacement Bulletin | Item no. | Summary | Added |
---|---|---|---|---|---|
FUEL SYSTEM, GASOLINE | |||||
01221 | 11/12/2001 | 630320 | Some dedicated compressed natural gas (cng) vehicles may exhibit a rough idle, or no start in cold conditions. *tt | 04/16/2002 | |
FUEL SYSTEM, GASOLINE - CARBURETOR SYSTEM | |||||
01M02 | 05/01/2001 | 620174 | Some of the composite intake manifolds used on 4.6l sohc engines may develop fatigue cracks at the coolant crossover duct. this condition could result in engine coolant leakage which, if not serviced, may cause engine overheating. compl | 07/19/2001 | |
01M02 | 03/01/2001 | 619445 | Owner notification program regarding additional coverage on certain 4.6l sohc intake manifolds. some of the composite intake manifolds may develop fatigue cracks at the coolant crossover duct. *tt | 05/31/2001 | |
14807 | 04/01/2001 | 619311 | Some vehicles may exhibit a hoot noise at idle coming from the induction system. possible additional symptoms may include diagnostic trouble code p1506 and a higher than normal idle. *tt | 05/23/2001 | |
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY | |||||
CSP 08B04 | 05/15/2008 | 10026401 | Ford/lincoln mercury: certain 1992-2001 model year crown victoria, grand marquis, and town car vehicles registered in the states of wisconsin and connecticut upgrade modifications for high speed rear impacts. *pe | 10/24/2008 | |
020503 | 03/21/2005 | 0556 | 636417 | Guidance for cng tank inspection for vehicles produced after december 2, 1996. *tt update. *tt | 11/08/2002 |
012114 | 10/29/2001 | 627791 | Parts and procedure to reduce the potential of fuel tank punctures during rare and extremely high-speed rear impacts. *tt | 02/25/2002 | |
14862 | 04/01/2001 | 619299 | Information on replacing fuel tank strap bolts. *tt | 05/23/2001 | |
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY - FILLER PIPE AND CAP | |||||
011809 | 09/01/2001 | 625839 | Some vehicles may exhibit a fuel filler door that does not fit correctly or the fuel door may inadvertently pop open. *tt | 12/04/2001 | |
011809 | 09/01/2001 | 625849 | Some vehicles may exhibit a fuel filler door taht does not fit correctly or the fuel door may inadvertently pop open. *tt | 12/04/2001 | |
01189 | 09/17/2001 | 625710 | Information on fule filler door, poor fit remote fuel door pops open.*jb | 11/30/2001 | |
FUEL SYSTEM, OTHER | |||||
0398 | 05/12/2003 | 10002780 | Malfunction indicator lamp (mil) illumination with diagnostic trouble codes p0442, p0455, p0456, p0457, p1442 or check fuel cap lamp illuminated with diagnostic trouble code p0457. *tt | 09/17/2003 | |
030409 | 02/01/2003 | 10002519 | Possible fuel leak at fill valve - fill valve service part revisions - cng vehicles only. *tt | 09/04/2003 | |
0349 | 03/03/2003 | 10001901 | A possible fuel leak may occur at the fuel fill valve on some cng (compressed natural gas) vehicles. *tt *jb | 07/25/2003 | |
FUEL SYSTEM, OTHER - STORAGE - TANK ASSEMBLY | |||||
CSP 08B04 | 05/15/2008 | 10026401 | Ford/lincoln mercury: certain 1992-2001 model year crown victoria, grand marquis, and town car vehicles registered in the states of wisconsin and connecticut upgrade modifications for high speed rear impacts. *pe | 10/24/2008 | |
0253 | 03/18/2002 | 636042 | Subject regarding alternative fuel vehicle compressed natural gas tank inspection. *tt | 11/04/2002 | |
15113 | 08/01/2001 | 624689 | Some vehicles may exhibit a fuel fill valve sealing condition. *yd | 11/08/2001 | |
FUEL SYSTEM, OTHER - STORAGE - TANK ASSEMBLY - FILLING/CHARGING | |||||
15271 | 09/01/2001 | 625804 | Dedicated cng regulator bowl kit available. *jg | 12/03/2001 |
Investigations
NHTSA ID | Manufacturer | Date open | Date close | Subject | Recall campaign | |
---|---|---|---|---|---|---|
FUEL SYSTEM, GASOLINE - STORAGE | ||||||
SQ01014 | FORD MOTOR COMPANY | 11/27/2001 | 10/03/2002 | POST REAR END COLLISION FIRES | 02I003000 | |
Allege fuel tank can rupture following a high-energy rear collision resulting in severe fires. | ||||||
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY | ||||||
EA03001 | FORD MOTOR COMPANY | 01/27/2003 | 11/19/2003 | CNG TANK EXPLOSION | 03V472000 | |
In september 2002, a fuel cylinder in a natural gas powered vehicle (ngv) exploded during a fire.ford and vrtc test engineers jointly examined the incident vehicle and reviewed testing to determine whether the performance of the pressure relief valve (prd) was proper.the purpose of a prd is to protect a compressed natural gas tank from overpressure by allowing the cng to vent when the temperature reaches a specific point.the prd was removed from the failed tank and subjected to a yield temperature determination test. it was concluded that a direct flame (from the interior of the vehicle) onto the cylinder (located behind the rear seat in the trunk)compromised the hoop strength of the natural gas cylinder, thus allowing the cylinder to fail prior to the prd releasing at itsdesigned temperature.as a result of this testing and review of the involved vehicle, ford has developed an insulator to insulate the natural gas fuel tank from a locally directed flame projecting from the interior of the vehicle.insulators will be installed behind the back seat on subject vehicles to prevent future failures of this type. ford's action addresses the concerns of odi.therefore, this investigation is closed. | ||||||
PE02071 | FORD MOTOR COMPANY | 10/01/2002 | 01/27/2003 | CNG TANK EXPLODING IN A FIRE | ||
An explosion of a compressed natural gas (cng) tank should not be able to occur, as the tank is fitted with a pressure relief device (prd). this prd should release the cng in the tank, prior to the pressure reaching the tank burst pressure.the prd did not release in the subject wisconsin police cruiser explosion.nhtsa has recovered the prd valve from the tank that exploded and testing will be necessary to establish why this tank safety valve did not release in the very high temperature fire that occurred in the police cruiser.there is only the single known event, but due to the catastropic force of such an explosion and the potential for injury and loss of life, this investigation is being upgraded. |
Consumer Complaints
Fail date | miles | occurences | Purchase date |
---|---|---|---|
FUEL SYSTEM, GASOLINE | |||
06/17/2008 | 120000 | ||
Tl*the contact owns a 2001 ford crown victoria. the contact stated that he worked for a company that had six crown victorias and one ford mustang. the gasket had to be replaced on the fuel tank from the filler pipe. when he filled the vehicle with gasoline, fuel would leak out on top of the hot exhaust. the contact noticed a trend and the company replaced the gaskets on seven vehicles. he is currently waiting for the part for the seventh vehicle, which is on backorder at every dealer in atlanta. he has not consulted the manufacturer. the current mileage was 120,457 and failure mileage was approximately 120,000. | |||
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY | |||
03/21/2003 | 15455 | 1 | 11/19/2001 |
The consumer was concerned about the gas tank shield being installed in police vehicles and not regular consumer vehicles. *mr the fuel tank shield was installed at the consumer's expense. *tt *jb | |||
This vehicle is equipped with the same fuel tank which has been recalled for police vehicles only. the consumer believes all crown victoria's should be recalled, not just the police fleets. *nlm | |||
11/05/2002 | |||
The vehicle fuel tank has a fuel leak. consumer states after filling tank with fuel, all the fuel leaked back out of the tank. please provide more details. ts | |||
06/01/2001 | |||
We are concerned to drive our crown vic because of the alleged fuel tank problems. we live in phoenix, az, and in the past three years four police officers have been either killed or severly injured due to collisions that resulted in the fuel tank catching fire. we would like to know what ford motor co. plans to do about this. is our crown vic safe to drive? if not, what do we need to do? if we retrofit the gas tank right now, we will void our warrenty. we are in a quandry as to what to do.*ak | |||
FUEL SYSTEM, OTHER - STORAGE | |||
Consumer called complaining about haviing problems with the gas tank. also stated that he knows that there is problems with this vehicle. dealer was not contacted at the time this phone call was done. ts |