Recalls


CampaignManufacturerManufacturing dateType# of units affectedDate Owner notified MfgRecall Initiated byManufacturers of recalled vehicles/productsReport Recieved DateRecord Creation DateRegulation Part NumberFMVSS Number
FUEL SYSTEM, GASOLINE
93V192000HYUNDAI MOTOR AMERICA to 10/01/1993V (Vehicle)25700105/11/1994MFRHYUNDAI MOTOR COMPANY11/23/199312/01/1993571301
Defect SummaryThe vehicles failed the lateral moving barrier impact test requirements of fmvss 301, fuel system integrity. the fuel leakage from the gas tank exceeded the maximum allowable amount of spillage.
Consequence SummaryIn the event of an accident, the fuel spillage can resultin a fire if exposed to a source of ignition.
Corrective SummaryHyundai has developed an appropriate countermeasure that will comply with all requirements of fmvss 301.
NotesSystem: fuel; fuel systems; fmvss 301.vehicle description: 3 and 4 door passenger vehicles.note: if your vehicle is presented to an authorized dealer on an agreed uponservice date and the remedy is not provided within a reasonable time and freeof charge or the remedy does not correct the defect or noncompliance, pleasecontact hyundai service center at 1-313-747-6600. also, please contact thenational highway traffic safety administration's auto safety hotline at1-800-424-9393.

Consumer Complaints


Fail datemilesoccurencesPurchase date
FUEL SYSTEM, GASOLINE
05/07/1996102/01/1991
 She requested the part from the manufacturer over a year ago and she still has not received the part regarding fuel system recall 93v192000. *ak
06/21/1995
 Hyundai zone office 93v192. owner tried to obtain a listing for nearest dealer to him. after second attempt he called nhtsa to try to have recall work performed