Neoplan An440 1992
Model An440 made in 1992 by Neoplan got 1 recall. There was one recall concerning fuel system, other .
Model 1992
Recalls
Campaign | Manufacturer | Manufacturing date | Type | # of units affected | Date Owner notified Mfg | Recall Initiated by | Manufacturers of recalled vehicles/products | Report Recieved Date | Record Creation Date | Regulation Part Number | FMVSS Number | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FUEL SYSTEM, OTHER - STORAGE - TANK ASSEMBLY - PRESSURE RELIEF DEVICES | ||||||||||||||||
95V188001 | NEOPLAN USA CORP. | from 06/01/1992 to 07/01/1994 | V (Vehicle) | 101 | 12/15/1995 | ODI | NEOPLAN USA CORPORATION | 08/30/1995 | 04/19/1996 | |||||||
Defect Summary | Some temperature sensitive triggers were not x-rayed. these triggers could contain internal voids that would make the triggers susceptible to advanced creep causing false activation and venting of the cng. | |||||||||||||||
Consequence Summary | Venting of the cng could result in a fire. | |||||||||||||||
Corrective Summary | Neoplan will replace the prd with the newer design generation 2.5 pressure relief device. | |||||||||||||||
Notes | System: fuel; cng; pressure relief valves/devices (prd).vehicle description: compressed natural gas powered transit buses equipped with lincoln composite cng fuel containers which incorporate mirada type iiipressure relief valves. (see mirada campaign 95e025 and lincoln composite campaign 95e025003).note: if the valves have not been replaced within a reasonable time free of charge, please contact neoplan at 1-719-336-3256.also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393. |