Recalls


CampaignManufacturerManufacturing dateType# of units affectedDate Owner notified MfgRecall Initiated byManufacturers of recalled vehicles/productsReport Recieved DateRecord Creation DateRegulation Part NumberFMVSS Number
FUEL SYSTEM, GASOLINE - DELIVERY - HOSES, LINES/PIPING, AND FITTINGS
87V139000FORD MOTOR COMPANYfrom 07/01/1985 to 08/01/1987V (Vehicle)360000010/12/1987ODIFORD MOTOR COMPANY09/04/198709/09/1987
Defect SummarySpring lock fuel line coupling may not be properly engaged.
Consequence SummaryCoupling could disengage due to fuel pressure,vibration, and engine movements; this would cause loss of fuel which, inpresence of an ignition source, creates a fire risk.
Corrective SummaryInstall retainer clips over the couplings to prevent coupling separation and fuel leakage.
NotesSystem: fuel line couplingvehicle description: passenger cars and light trucks equipped with fuelinjection.

Investigations


NHTSA IDManufacturerDate openDate closeSubjectRecall campaign
FUEL SYSTEM, GASOLINE
DP89005FORD MOTOR COMPANY01/26/198908/01/1989F-SERIES FUEL TANK FIRES
 F-series fuel tank fires

Consumer Complaints


Fail datemilesoccurencesPurchase date
FUEL SYSTEM, GASOLINE
06/13/200385000106/07/1986
 1986 ford f150 with dual fuel tanks, fuel siphons from one tank to the other, tank overflows causing spillage on ground. same problem with check valve on ford f150 models during 1990 to 1993 resulted in a recall. dangerous situation could result in fire or explosion. *nlm
 Truck was parked off and caught on fire . tt
FUEL SYSTEM, GASOLINE - DELIVERY - FUEL PUMP
10/07/1996108/28/1996
 The rear fuel tank is defective due to design, potentially explosive . *ak consumer states he pulled the pump out of the tank and saw that it had burned the center out of the pump. *slc
FUEL SYSTEM, GASOLINE - STORAGE
06/06/19961
 Fuel pressure regulator failed, causing gas leak.
FUEL SYSTEM, GASOLINE - STORAGE - AUXILLARY TANK
07/05/2001207/01/2001
 Fuel is leaking from one tank to another tank, causing an overflow, and allowing excessive amount of fuel to leak onto ground due to crossflow condition, check valve failuire.*ak *slc
FUEL SYSTEM, GASOLINE - STORAGE - AUXILLARY TANK - SELECTOR DEVICES
02/01/2002201/30/2002
 After filling both tanks, front tank's fuel would pour into and out of rear tank. took to mechanic, and problem could not be resolved. *ak consumer was advised by manufacturer to get truck fixed as soon as possible as this is a dangerous part failure. *tt
07/05/2001207/01/2001
 Fuel is leaking from one tank to another tank, causing an overflow, and allowing excessive amount of fuel to leak onto ground due to crossflow condition, check valve failuire.*ak *slc
01/15/1998
 The truck has duel fuel tanks and the fuel does not switch over from one tank to another. the dealer is aware of the problem. the problem has not been corrected.
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY
01/01/1997205/14/1986
 Rear gas tank rusted through at top, causing gas to leak out.
10/07/1996108/28/1996
 The rear fuel tank is defective due to design, potentially explosive . *ak consumer states he pulled the pump out of the tank and saw that it had burned the center out of the pump. *slc
10/15/1994
 While driving, noticed in rearview mirror flames were coming up between cab and bed; equipped with plastic fuel tanks; exact cause of fire unkown. *ak
FUEL SYSTEM, GASOLINE - STORAGE - TANK ASSEMBLY - MOUNTING
04/01/19951
 Fuel tank straps failed.