Bulletins


BulletinBulletin dateReplacement BulletinItem no.SummaryAdded
VISIBILITY - DEFROSTER/DEFOGGER SYSTEM
240120109/14/2001625576Customers may complain that the hvac drain water leaks under passenger side carpet. *tt11/29/2001
24219910/08/1999612190Vehicles may experience water dripping from the bottom of the evaporator drain tube and enter the passenger compartment causing wet carpet or water on the passenger compartment floor. *mjs06/06/2000

Consumer Complaints


Fail datemilesoccurencesPurchase date
VISIBILITY
08/09/2008168031
 A/c-heater fan control switch burns out every 2 to 4 years. i am the original owner of a 99 jeep tj wrangler. i have replaced the fan control switch 4 times now. each time the pigtail has fried as well and needed replacing. first time dealer replaced under warranty. second, third and fourth time i paid to have it replaced. after 3rd time i wrote to chrysler and explained and showed all dealer repair paper work and they reimbursed with check for one repair. dealer gave me a credit on an additional repair. this last (4th) repair i found out that chrysler knows about the issue, and has reduced the price of the replacement part by half. i was told to expect this to be a normal repair every 2 to 4 years for as long as i have the vehicle. i was told for a few model years they have constant power to the fan and this eventually leads to a burn out. sometimes causing more damage if the flareup is big. chrysler won't do any more reimb. and no plans to fix model years affected. bummer!! repair dates: 7/2000; 8/2002; 9/2004;8/2008 part number: 55037473ab. *tr
VISIBILITY - DEFROSTER/DEFOGGER SYSTEM
01/01/19011
 1999 jeep wrangler with ground wire problems **answered by ric willard** cc the recall was 99v117000. the vehicle was taken to the dealer for the recall. after the repairs the problem persisted. the consumer reached behind the cluster and when he pushed on one of the plugs they moved about an eighth of an inch. the consumer then heard the latched snap into position and he hasn't had a problem since. the heater also had a problem that the consumer thought would be corrected by recall but was not. the system changes the location of the air flow on it's own. *nm
06/25/199906/01/1999
 Anytime i turn the defogger during rain water comes into the vehicle.*ak
VISIBILITY - DEFROSTER/DEFOGGER SYSTEM - WINDSHIELD - BLOWER
01/01/200675000106/23/1999
 If hvac system is left on maximum heat setting for a length of time, the contacts in the fan speed selector switch melt causing failure of some or all of the fan speed modes and require switch replacement. *tr
08/31/20044500010
 Same electrical cut off problems. constant burning wire smell. defrost knobs, and high med low knob stays on low or high, or nothing. knobs and motors have been replaced 1 time. different dealers in chicagoland and central il say there is nothing wrong nor any recalls that have to do with this. tired of spending money. top of vehicle is very worn, seams are busting out and top is becoming unsafe. driverside window zipped fell off. jeep is garaged daily and taken care of but is falling apart.
02/08/2004211/18/2002
 Defroster/heater blower motor and switch quit. replaced at least once before, within a year & a half. first, only one speed on the fan works then nothing.
VISIBILITY - DEFROSTER/DEFOGGER SYSTEM - WINDSHIELD - CONTROLS/WIRING
01/01/200675000106/23/1999
 If hvac system is left on maximum heat setting for a length of time, the contacts in the fan speed selector switch melt causing failure of some or all of the fan speed modes and require switch replacement. *tr
04/04/200240000612/05/2000
 Problems with back and door latches breaking and jamming making it impossible to open the doors. also, flimsy plastic sleeves that connect the a/c/fan/temperature knobs to the control panel break easily making it impossible to use the defroster and panel fans, heater, and a/c.*ak
VISIBILITY - DEFROSTER/DEFOGGER SYSTEM - WINDSHIELD - HEATER CORE
08/14/20079700010009/16/2005
 Make / models : jeep / wrangler model/build years: 1999 manufacturer : daimlerchrysler corporation nhtsa campaign id number : 99v117000 chrysler say no recall but i have this problem what do i do?? thank you very much gages go dead, no heater fan *tr
103/07/2002
 Consumer began smelled something burning. heater control knob melted. heater motor started to come on and off on its own. *ak
VISIBILITY - REARVIEW MIRRORS/DEVICES
03/01/1999
 Through research it was brought to my attention that a bad paint job can cause the windshield to fall out of its frame. chrysler recently painted my car under warranty but did a horrible job. the following website suggested reporting this problem to this organization: https://www.nhtsa.dot.gov/ivoq/oscripts/ivoq/voq/voq6.cfm i would also like to add that chrysler left both the windshield and drivers side mirror on my car damaged.
VISIBILITY - WINDSHIELD
05/15/2002109/01/2098
 Car was parked in garage when window glass exploded. glass was inbedded into concrete wall. nothing struck or damaged the window. i was in the process of lowering it, (it is on hydraulic suspension so can not be slammed.*ak
03/01/1999
 Through research it was brought to my attention that a bad paint job can cause the windshield to fall out of its frame. chrysler recently painted my car under warranty but did a horrible job. the following website suggested reporting this problem to this organization: https://www.nhtsa.dot.gov/ivoq/oscripts/ivoq/voq/voq6.cfm i would also like to add that chrysler left both the windshield and drivers side mirror on my car damaged.